Application
The control cable are suitable for the connection of controlling electrical equipment and instrument monitoring and controlling return circuit, electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.


Property:  

(1)The long-term permissible working temperatures are: PVC 70°C, XLPE 90°C
(2)When laying the cable, the ambient temperature of laying should not be lower than 0°C.
(3)When it is flexible structure, not armored but with screen, the minimum bending radius is ≥6D; When it is armored or with copper tape screen, the bending radius is ≥ 12D(D is the cable overall diameter).
 
Construction

Main Specs: 2~61 Core: 0.75~2.5mm²; 2~14 Core:4~6mm²; 2~10 Core: 10mm²


Standard

The products can be produced according to the Chinese standard GB9330-1998,and the factory can also manufacture the cables following other standards.

Specification

Type

Name

Section Area(mm2)

No. of Core

Application Site

KVV

Copper Conductor,PVC Insulated and Sheathed Control Cable

0.75 1.0 1.5 2.5

2-16

Permanent installation indoors,in cable ditches or pipes



4 6

2-14




10

2-10


KVVP

Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded  Control Cable

0.75 1.0 1.5 2.5

2-61

Permanent installation indoors,in cable ditches or pipes where shielding is required



4 6

2-14




10

2-10


KVVP2

Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable

0.75 1.0 1.5 2.5

4-10

Permanent installation indoors,in cable ditches or pipes where shielding is required



4 6

7-61




10

4-10


KVV22

Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable

0.75 1.0 1.5 2.5

7-61

Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force



4 6

4-14




10

4-14


KVVR

Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable

0.5-2.5

4-61

Installation indoors where flexibility and movability are required

KVVRP

Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable

0.5 0.75 1.0

4-61

Installation indoors where flexibility shielding and movability are required



1.5 2.5

4-48


KYJV

Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable

0.75 1.0 1.5 2.5

2-16

Permanent installation indoors,in cable ditches or pipes



4 6

2-14




10

2-10


KYJVP

Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable

0.75 1.0 1.5 2.5

2-61

Permanent installation indoors,in cable ditches or pipes where shielding is required



4 6

2-14




10

2-10


KYJV22

Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable

0.75 1.0 1.5 2.5

7-61

Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force



4 6

4-14




10

4-10


KYJVP2

Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable

0.75 1.0 1.5 2.5

7-61

Permanent installation indoors,in cable ditches or pipes where shielding is required



4 6

4-14




10

4-10


KYJVR

Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable

0.5-2.5

4-61

Installation indoors where flexibility and movability are required

KYJVRP

Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable

0.5 0.75 1.0

4-61




1.5 2.5

4-48

Installation indoors where flexibility shielding and movability are required